OH

Overheat Protection (Heater is deactivated, filter/circulation pump is activated).  Water temperature is above acceptable limits. Do not enter the water! Remove hot tub cover to speed cooling. If condition persists, contact your Sundance Spas dealer to schedule service.

COOL

If the hot tub water is more than  -7°C cooler than the temperature setpoint, jets pump #1 and heater will automatically activate to provide freeze protection. The hot tub will stay in this mode until the water temperature reaches 15 degrees below the set temperature. No corrective action is necessary.

FLO

FLOW SWITCH (Heater is deactivated. The filter/circulation may also be deactivated). Proper flow of water is inhibited or a flow switch has malfunctioned. Check for proper water level and for clogged filter. 

HOT

Circuit board temperature has exceeded acceptable limit. This message will disappear when the circuit board temperature drops below acceptable limit. If condition persists, provide shade for equipment side of hot tub or contact your Sundance Spas dealer to schedule service.

ICE

FREEZE PROTECTION A potential freeze condition has been detected. No action is required. Jets pump(s) operate until the hot tub is out of danger.This error commonly occurs when the hot tub is first filled because tap water is often very cold.

PF

Power fluctuation in the secondary power line is causing the DC voltage to be low. Try to reset power to spa. If the error returns, contact your Sundance Spas dealer to schedule service.Contact your Sundance Spas dealer to schedule service.

PnL 

Communication between the control panel and/or remote control panel and circuit board is faulty. Contact your Sundance Spas dealer to schedule service.

SN1-SN3

OPEN SENSOR (heater disabled) or SHORTED SENSOR (hot tub is deactivated) The high-limit or temp temperature sensor is non-functional. This must be repaired only by an Sundance Spas dealer, call to schedule service.

FLO2-ICE2

CLOSED or SHORTED FLOW SWITCH ON SYSTEM STARTUP (system disabled) Flow switch is non-functional. This must be repaired only by a  Sundance Spas dealer, call to schedule service.

– – –

“WATCHDOG” (hot tub is deactivated). Water temperature is above acceptable limits. Do not enter the wat er! Remove hot tub cover to speed cooling. A problem has been detected which could cause damage to the hot tub or its components. Contact your Sundance Spas dealer to schedule service. 

Additional Information

Manufacturer

Sundance Spas

Reviews

There are no reviews yet.

Be the first to review “Sundance Spas Error Codes”

Minnsota Hot Tubs Bullfrog Spas
Minnsota Hot Tubs Hawaiian Breeze Spas
Minnesota Hot Tubs Nordic Spas
Minnsota Hot Tubs Visscher